FloraPulse

The SDI-12 box on a METER ZL6

For researchers. 2 min.

Chapters

  1. 0:00 The SDI-12 box on a METER ZL6
  2. 0:16 Read the number
  3. 0:33 Batteries
  4. 0:51 If nothing shows
  5. 1:13 Then the box’s mode
  6. 1:33 The steps, on the troubleshooting page

What the film says

The SDI-12 box on a METER ZL6

A FloraPulse SDI-12 box can be read by a METER ZL6 logger, when the box was ordered for one. It arrives with a compatibility mode built in, and a plug that goes straight into a logger port.

Read the number

The logger labels the reading as soil matric potential, in kilopascals. Read the number. Divide the kilopascal reading by 100 to get bar. −1500 kilopascals is −15 bar of stem water potential.

Batteries

The box takes about a third off the logger's battery life. We recommend lithium cells, with the battery type set to Lithium. After any battery change, connect ZENTRA Utility right away, because connecting sets the logger's clock.

If nothing shows

If nothing shows, check the logger's battery percentage first. Then check that the plug is fully seated. If the box was ever moved, its old port keeps reporting no response, until you update that port's sensor configuration in ZENTRA Utility and press the logger's TEST button.

Then the box’s mode

If the logger still does not find the box, check the box's mode on the calibration page, with the box on the USB uploader. Use Mode 2 on the ZL6, with the box at address zero. After setting the mode, unplug the box at the logger and plug it back in.

The steps, on the troubleshooting page

The steps are on the troubleshooting page. If it still shows nothing, send us the logger model, its battery percentage, the port, and a data export.